2019/08/21

How to setup Cummins Insite 8.5.0 on Windows 7?

Cummins Insite 8.5.0 is released and tested OK with Inline 6 and Inline 7 HQ china clone.
Here’s the installation instruction of Insite 8.5.0.57 program + driver + patch and test report on Inline 6 adapter. Hope it’s helpful.

you should have:
folder: drives
zip file: INSITE 8.5.0
zip file: INSITE 8.5.0 patch
install-cummins-insite-850-sw-1

operating system:
windows 7 32 bit: tested!
(need luck for other windows edition)

youtube video:

steps to install cummins insite 8.5.0:

step 1: install insite 8.5.0 program
step 2: install driver for cummins inline 6
step 3: install insite 8.5.0 patch

in detail…

step 1: install insite 8.5.0

establish a new folder: 8.5 on Desktop
extract INSITE 8.5.0.exe to the new folder 8.5
open folder 8.5
run AdminInstall as admin
select a setup language (here: English)
install-cummins-insite-850-sw-2
start to install insite 8
install-cummins-insite-850-sw-2
items required to install:
Microsoft.NET Framework 4.7.1 Full
Microsoft_Visual_C++_2017_Redistributable_Package_(x86)
TooLicenseService
INSITE Data Pack

start to install items one by one
note 1: accept insite software license agreement
note 2: insite data pack is installed successfully
install-cummins-insite-850-sw-3
finish, but you will get an error: some files may be missing from the installation or computed. please reinstall or repair and relaunch application
leave the error aside and continue your installation
note 3: install insite – installshield wizard
next – tick on “I have verified…”, next – accept the license agreement, next – next – install
install-cummins-insite-850-sw-4
insite is installed successfully
install-cummins-insite-850-sw-5
finish

automatically install insite 8.5.0, insite manager, fault viewer
install-cummins-insite-850-sw-6
then click on OK on the error

go to folder 8.5 – UpdateManager
open fix application
go to Help –fix bug, then exit
install-cummins-insite-850-sw-7

step 2: install insite 8.5.0 driver

go to Computer Properties to confirm your system type
here: 32 bit operating system
install-cummins-insite-850-sw-8
go to the removable disk INISTE 8.5.0, then folder drives – inline 6 drivers
open the zip file: inline-6-9-0-0-32bit, then do extraction from it
automatically running…
will install Cummins INLINE 6 -32bit on your system
next…
finished installing Cummins INLINE 6
finish

step 3: install insite 8.5.0 patch

copy the zip file INSITE 8.5.0 patch from the removable disk to Desktop
extract the pactch file on Desktop, then open the folder
open “康明斯8.5.0注册” (cummins 8.5.0 registration) application
install-cummins-insite-850-sw-10
install-cummins-insite-850-sw-11

accept cummins license agreement
cummins inline 6 driver software will  be installed automatically

step 4: configure cummins inline 6 connection

open Cummins INSITE app
accept insite software license agreement
add new to create a connection to a datalink adapter or ecm simulator
install-cummins-insite-850-sw-12
rp1210 adapter: connect using a rp1210 adapter
install-cummins-insite-850-sw-13
connection settings:
vendor: cummins inc. inline 6
adapter: inline 6 usb
protocol: auto detect
install-cummins-insite-850-sw-14
connection name: INLINE 6.USB (Auto Detect) Connection
to make this connection active, select this box and then click FInish
install-cummins-insite-850-sw-15
successfully configured the new connection

connect
install-cummins-insite-850-sw-16
install-cummins-insite-850-sw-17
fault codes in cummins insite 8.5.0
install-cummins-insite-850-sw-18
inline 6 clone adapter is confirmed to work with insite 8.5.0.
aslo, it can be used with Cummins inline 7 china clone. tested and worked good.

2019/08/15

Where to get Cummins Insite 8.5, 8.3, 7.6 for Inline 5 6 7

Good to know: The latest Cummins insite 8.5 is released!
cummins-insite-8.5
Now , you have luck with Cummins insite new and old versions. incl
insite 8.5, insite 8.3, insite 8.2 and insite 7.6 for inline 7, inline 6, inline 5

I. Cummins insite 8.5 (Latest version)

This is Cummins insite 8.5 software + patch:
Need activation for the authorization
Confirmed to do diagnostic test and ECU data reflash
Tested OK with cummins inline 6 data link adapter & NEXIQ2 usb link
cummins-inline-6
Will test with inline 7  adapter and update info here…

Cummins insite 8.5 basic introduction:

Version: 8.5.0.57
Year: [03.2019]
Type: Diagnostics Software
Make: Cummins
Region: WorldWide
Language: English
OS: Windows 7 32 bit, Windows 7 64 bit, Windows 8/8.1 32 bit, Windows 8/8.1 64 bit, Windows 10 32 bit, Windows 10 64 bit

Features:
• Quick access to trip information
• Adjust parameters and review/clear fault information quickly and easily
• Easy-to-follow troubleshooting assistance
• Wiring and sensor location diagrams
• Store engine and trip information for future use, or as programming templates

Description:
Cummins INSITE v8.5 Pro is a PC-based software application that provides quick and easy access to your engines electronic performance information, which enables faster service turnaround times. INSITE helps to ensure accurate procedures and diagnosis and limit downtime while increasing productivity and profits.
The current version is v8.5 with professional level access.
Cummins INSITE software supplies engine information quickly, getting the inside details you need. No matter what kind of equipment you run, INSITE is the one support product to have in your virtual toolbox to fit every Cummins electronic engine.
INSITE performs engine diagnostics and displays electronic engine information on your PC.
With step-by-step diagnostics, built-in engine drawings and schematic diagrams, working with INSITE is easy.
Using this software application will reduce troubleshooting time, errors and incorrect procedures and quickly get your vehicle back on the road again.

II. Cummins insite 8.3
cummins-insite-8.3
Insite 8.3 software (2013) comes with Cummins Inline 7 adapter
cummins-inline-7
The software is authorized for free, what the user to do is enter the serial number.
No need change the computer date and time.
Easy to install on Windows 7, Windows 8, Windows 10.

Here is the insite 8.3 crack installation instruction:
  1. Inline7 runs the same driver as Inline6
  2. Software activation is done via server. Need to confirm by server and it may take some time, after success, the software is combined with your computer.
  3. Do not directly open the Inline 8.3 after installed, you need to go through the server software and use Inline 8.3.
  4. After Inline 8.3 is authorized successfully, users can use 3 years for free for 70 times, generally the user is supposed to get authorization every month (that is within 3 years, after the times is used up, users can get authorization by themselves). After 3 years, you need to pay extra license.
5.After activation, users are not allowed to change laptop motherboard, RAM and CPU. If you change them, you have to submit the Inline 7 serial number to the seller for activation.
  1. The Calibrations in the Inline 7 U disk can be used for 6 months only, after 6 months later you can search “Inline Calibrations”online and download to use.
7.If you install Chinese version insite 8.3, then you have to run “Cummins License Configuration tool” in Chinese; if you choose the other language to install insite 8.3, then run the “Cummins License Configuration tool” in English, because the dealer code is not the same.
Chinese dealer code: 010C
English dealer code: 086N
8.After input Dealer code and serial number, please click on ” Payment success”, then provide the dealer with the serial number for processing in the server. When it is done, click on ” Payment success” again and you will receive a message indicating success.


cummins-insite-8.2
When installing insite, you need to change the computer time which is not easy to do.
Cummins insite 8.2 works with Inline 5 or 6 but runs on Windows 7 ONLY!
cummins-inline-6-data-link
cummins-inline-5


IV. Cummins insite 7.6
cummins-insite-7.6
Insite 7.62, the best insite version for some Inline 5 users since new versions 8.xx (Insite 8.2) have to communicate online with their mother ship(Cummins) and if they can’t, will stop working. If you want Insite 8.xx, forget cummins insite download for free! Spend some dollars and go to cummins insite crack version – never upsets users.

The good is that, Insite 7.62 also work on the newer engines like CM2350, CM2250, CM871, CM870 and some others.

The last,
For better, Inline 5 is advised to used with Insite 7.62.
You should have a new one if Insite 8.3, coz it only works for Cummins Inline 6 and Inline 7 adapters. if Insite 8.5, you should have inline 6 only (tested on Aug., 2019)

2018/12/05

Cummins INSITE 8.2 Download for Inline 4/5/6/7 Adapters

Free download Cummins INSITE 8.2 with installation and activation help to make it work with new and old inline 4/5/6/7 adapters. Here are two versions for you, one with free activation for 15-day trials only, the other with 500 times to use once activated.

Part 1: Insite 8.2 FREE version:

Here is the Cummins INSITE 8.2.X installer that tests all levels of functionality
Members copy patch files to C/Intelect/INSITE/XMLData folder and shortcut to desktop
Copy code gives me free activation 15 trials.
UNKNOWN SECURITY! You’re trying the free insite at your own risk!


Cummins INSITE 8.2+Full KG PRO top, fleet calibration and flash ecm feature list
1. Authorization file generator
2. Username generated authorization file
3. Is it bound to a computer (Cancel is not limited to computers)
4. Lock the CPU to lock the serial number of the hard disk
5. Bind the MAC Address to the BIOS Information
6. Check the limit and enter the appropriate value. Unchecked is no limit.
7. Valid expiration time
8. Limit once per minute
9. Limits can run for a total of minutes
10. Limit attempts to limit trial dates


Part 2: Insite 8.2 TESTED version:

Here is the 100% tested version. You can use the Insite 8.2 pro or lite version with security and relief. You have 500 times for use once your insite is activated.

Insite 8.2 remote installation & activation service:
cummins-insite-v820-download
A good tip: Iniste pro vs Insite lite

Insite 8.2 installation help:
You will have luck with Windows 7/8/10. But on Windows 10, pls run as administrator

Insite 8.2 and Inline 4/5/6/7 adapters:

Inline 5: no longer produced

Do not substitute cables, except as indicated in the INLINE 5, 6, or 7 Product Announcement Bulletin.
Incompatible cables may damage the INLINE 5, 6, or 7 adapter or personal computer and will void warranty.
Incompatible cables may cause communication issues with INSITE.
INLINE 5, 6, and 7 adapters may intermittently lose communication. If your Datalink adapter has communication problems, disconnect power from the adapter for 5 seconds and then reconnect. The INSITE program does not need to be shutdown.
There is a feature under Tools > Reset Datalink Adapter that may correct some software communication errors with the INLINE 5, 6, and 7.
The main harness (backbone) has a maximum overall length of 40 meters.
A J1939 stub, which can be a connection point for ECM’s and/or the INLINE 5, 6, and 7 Datalink adapter, cannot exceed a maximum length of 1 meter.
At each end of the backbone harness is a terminating resistor with a nominal resistance of 120 Ohms, it will measure 60 Ohms when you measure across the Datalink.
The INLINE 5, 6, and 7 adapters should be connected to a continuous battery power supply. When making adjustments with INSITE, including calibration download, the operator will be asked to switch the key off. If the adapter is getting its power from a power source dependent on the key switch status, such as the lighter adapter inside the cab, the adapter will lose power, which will result in INSITE losing connection to the ECM. This will require the operator to reconnect to the ECM and the adjustments might not have been saved.

Insite 8.2 protocols:
Engine Model Years 2007 and newer only support the J1939 protocol. Please refer to the following table for specific information:
cummins-insite-protocol
Note: The INLINE 4 adapter is obsolete. It can be used with INSITE, but technical support for this adapter is no longer available.

INSITE 8.2.0 released notes:
1  Opening INSITE
  1. Installation
  2. Connections
  3. Advanced ECM Data
5.Calibrations
  1. Display Graphics
  2. ECM Diagnostic Tests
  3. Fault Codes
  4. Printing
  5. Simulators
  6. INSITE Integrated Simulator – Single and Multi-Module
  7. Work Orders/ECM Images/Templates

In detail…

1 Opening INSITE
INSITE 8.2.0 takes longer to open if the computer has been restarted. Issue is currently under investigation.

2 Installation
INSITE 8.2.0 does not support Windows® XP or Windows® Vista. INSITE version 8.2.0 will only operate on PC’s running either Windows® 7, Windows® 8 or Windows® 10.

Refer to the table below for the hard drive space required for the installation of
INSITE 8.2.0. This is based on the assumption that the Operating System is installed
on C:\

Hard Drive Space Requirements
– Upgrade from 8.1.3: 350MB
– Fresh Install: 500MB

NOTE: It is highly recommended that you always reboot your PC after installing software

3 Connections
Error Messages for communication failures:
Error 5200: Indicates communication loss between computer and the datalink adapter.
Error 5201: Indicates communication loss between the datalink adapter and the ECM.
Error 5202: Indicates no communication could be established between the datalink adapter and the computer.
Error 5204: Indicates no communication could be established between the datalink adapter and the ECM.

If the “Auto Configure” and/or “Datalink Adapter Connection Test” do not find the adapter when connected, manually configure the Datalink adapter connection.
An Internet connection is required before selecting the following URL’s from the Help > About INSITE menu: http://www.cummins.com or http://insite.cummins.com

4 Advanced ECM Data
If the display becomes distorted or cannot be completely viewed, close the Advanced ECM Data window and then reopen it. Resizing the window can cause the view to become distorted.

5 Calibrations
Automotive applications will have a default setting of “ON” for the Save and Restore option in the Calibration Download dialog.
Industrial applications will have a Default Setting of “OFF” for the Save and Restore option in the Calibration Download dialog.
When performing a Calibration Download, the “Save and Restore” option may be grayed out for some applications.
To decrease calibration download times, please insure that all applications other than INSITE are closed. Always use the J1939 protocol and engine connector when available.
Computers with less than the minimum recommended hardware requirements will have an extended Calibration Download time. Screen savers and suspend modes should be disabled

6 Display Graphics
The use of Large Toolbar Buttons will not display all icons on the toolbar. Work Around: Under Tools > Options > General, select Small Buttons in Display Options.
Dual Monitors are not supported by INSITE.
To disable the “Display Feature Names” option for the view bar, uncheck the box in Tools > Options > General > Viewbar > Display Feature Names.
If your PC monitor display is set to “Large Fonts”, some information in INSITE may not be displayed. It is recommended to use small fonts.

7 ECM Diagnostic Tests
If the display becomes distorted or cannot be completely viewed, close the ECM Diagnostic Tests window and then reopen it. Resizing the window can cause the view to become distorted.

8 Fault Codes
The MIL Lamp Status is not displayed when printing the Image Fault Codes in Tool Display Format.
Work Around: Print the Image Fault Codes in Text Only Format or connect to the image, open Fault Codes and select the Print icon.

9 Printing
When using print preview, use the tool bar magnifying glass to display the text in a larger view. The Print options will be disabled when no printers are available. This includes the Page Setup, Print and Print Preview options. Work around: Setup/install a printer on the PC and retry the INSITE print selection.

10 Simulators
Values shown in simulator do not reflect real values that would be seen when connected to an engine.

11 INSITE Integrated Simulator – Single and Multi-Module
All simulators for the 2007 models and above were combined into one single simulator called INSITE Integrated Simulator – Single Module and INSITE Integrated Simulator – Multi-Module. These will display all the Features and Parameters, ECM Diagnostic Tests, and Advanced ECM Data that is supported for single and multimodule engines.

12 Work Orders/ECM Images/Templates
Double clicking on the exported image files (.csv format) will not open them with the correct format in Microsoft Excel. Work around: Follow the steps below to open an exported (.csv format) image file in Excel:
  1. Open the .csv image file with Microsoft Excel
  2. Highlight column A
  3. Click on Data > Text to Columns
  4. In Step 1 of the wizard, make sure the “Delimited” option is selected and click “Next”
  5. In step 2 of the wizard, uncheck the “Tab” box and check the “Comma” box and click “Next”
  6. In step 3 of the wizard, click on “Finish”
  7. Format columns as desired.
When upgrading to INSITE 8.2.0, the following file and folder need to be backed up:
C:\Intelect\INSITE\UserSettings\data.wo
C:\Intelect\INSITE\WorkOrders
Alternatively, select the “Export All” from the right-click menu while highlighting any Image.
When using templates, it is recommended to verify the first template sent to the target vehicle. This helps ensure the template configuration is correct for subsequent vehicles.
When using templates, verify that the ECM code is compatible or the same.
When naming images and templates, special characters cannot be used (i.e. & ^, etc.).

Insite 8.2 images:
cummins-insite-v820-software-1

cummins-insite-v820-software-2

cummins-insite-v820-software-3

cummins-insite-v820-software-4

cummins-insite-v820-software-5
http://blog.obdii365.com/2018/12/06/cummins-insite-8-2-download-free-version/

2018/07/24

How to Change Road Speed Parameters with Cummins Insite

Tips here to help change road speed parameters using Cummins Insite software.

Maybe you have to bring the bus in for a repair. Maybe you got home with a new bus and cannot remember how to adjust the speed as required by the state.

NOTE: This Carolina Thomas Bus Buzz assumes you have a service department laptop with the Cummins Insite Software (official or cheap crack version confirmed to work no issues).
If you do not have Insite you can learn some of what it can do or call us and we can get you what you need.

Step 1: Connect the laptop to the bus by using the 9-pin diagnostic receptacle inside every C2 located above the driver’s left foot position.
cummins-insite-change-speed-parameters-1
cummins-insite-change-speed-parameters-2

Step 2: Click on on your desktops Cummins INSITE Icon.
cummins-insite-change-speed-parameters-3
Step 3: Turn key in bus to on position. Bus does NOT need to be running.
Step 4: Click on on “Connect to ECM” menu on left and then click on “Connect” in pop up window.
cummins-insite-change-speed-parameters-4
Step 5: Click on on “Features and Parameters”.
cummins-insite-change-speed-parameters-5
Step 6: Scroll down menu to Road Speed Governor and click on on icon beside to expand its options. The menu is in alphabetical order for ease of use.
cummins-insite-change-speed-parameters-6
Step 7: Double click on on MPH number on MAX VEHICLE SPEED.
cummins-insite-change-speed-parameters-7
Step 8: Enter the new MPH speed required and then click on on the number. Note: North Carolina has specific laws for buses in operation. Please adhere to these laws for any bus in-service.
Step 9: Double click on on MPH number on MAX ACCELERATOR SPEED and change to same value as MAXIMUM VEHICLE SPEED.
NOTE: New speed is displayed and old speed is displayed to the right.
cummins-insite-change-speed-parameters-8
Step 10: On tool bar at top of screen, click on on the small computer icon to send info to engine’s ECM.
cummins-insite-change-speed-parameters-9
Step 11: Pop up window will indicate you are to turn ignition key off for 30 seconds. Do this and then click on OK.
cummins-insite-change-speed-parameters-10
Step 12: NEW pop up window will tell you when to turn ignition key back on. When instructed, turn key on and click on OK.
cummins-insite-change-speed-parameters-11
Step 13: Pop up window will indicate when all parameters were successfully written. Click on OK.
cummins-insite-change-speed-parameters-12
Step 14: Click on Icon on left to disconnect from ECM. When this is complete it is safe to remove laptop connections with bus.
cummins-insite-change-speed-parameters-13