Showing posts with label cummins insite. Show all posts
Showing posts with label cummins insite. Show all posts

2020/06/21

Free Download June 2020 Cummins INCAL Calibration File

On May 14th, Cummins released June 2020 Incal on their download site. For those still using Insite 7.6,  here converted & uploaded all 5 disc’s into one download (CalibrationWorkspace) to Mega.nz.
INCAL is a DVD set that has a complete list of current ECM calibrations for INSITE.  The folder is massive at 39.6gb and will expire on December 2nd 2020 as will the original download from Cummins.

06.2020 Cummins INCAL DVD Calibration Files Download FREE:
No Pass.   This is for Insite 7.6 Only.
File including:
cummins-incal-2020-june
It has been tested on a ISC & ISB CM2150 engines using an Inline 6, it re-calibrated both ECMs without any problems.
– O.S.: Windows XP, Windows Vista, Windows 7, Windows 8, Windows 8.1, Windows 10
– CPU: Pentium/Athlon 2 GHz or higher
– RAM: 512 MB of system memory
– Hard Drive: 10 GB of available space
– Optical Drive: DVD-ROM
cummins-insite-852
To get the best diagnostic testing and full engine coverage, We would recommend using Insite 8.5.0 or later and using calibrations downloaded direct from Cummins.

2020/05/27

Free Download Cummins Insite 8.5.2 with Keygen

Free download Cummins Insite 8.5.2
The file is clean but some virus scanner will flag it.
Update to Cummins Insite 8.5.2 only enjoy!!!!
cummins-insite-v852
Source: MHH forum.

*** Please try the link at your own risk, the editor is not responsible for any error it may bring you.

How to Install Insite 8.5.2?
1. First unzip 8.5 and run “admininstall” as admin.’ Once Install go to Step 2.
2 Use “Cummins Update Manager and upgrade 8.5 to 8.5.2 ( that means do all update First to 8.5.1 then to 8.5.2)


How to activate Insite 8.5.2?
This method use a sideloader just like 8.3 so will need run 8.5.2 in Simulation mode.
Put the Sideloader folder on your C: Drive
Next go into the folder and you will see “Cummins Insite 8.5.2” Create a destop shortcut to your desktop
Next go to Keygen folder and navigate to folder “EXE” inside that folder you wiil see WLGEN run it
Next double click on your shortcut desktop icon for the Insite 8.5.2 that you made you it will show HWID don’t worry you don’t need to write it down it
will auto copy the hwid
Go back to the WLGEN tool and click on License Manager and then click ” Add License ” Put any Customer name you want  next click Hardware ID and right click to paste the
Hardware ID into the spot.
Make sure set a Date of Experiation or else the sideloder will not work
Next click save then to Create License Key Now go look into the folder that is just made and copy the registery.dat file
Place that file into the sideloader Folder on the C drive that has Cummins 8.5.2 sideloader
Now go back to your desktop and launch 8.5.2 shortcut > I will repeat if ask you click on the simulation


For the Folks don’t know to use the program
This work’s like 8.3  so the zapit and fleet counts are built into the side loader you don’t need no key’s
Only way the zapit will work or show up is to be connected to the ECM. Once connected to a lock ecm it will show up after a few minutes…

Update on 03/31/2020:
For those of you are having problem doing the updates of the folder, the solution is easy.
Run update manger as admin
Then drop the box down to “browse”
Then do the update folder in order
First 8.5.1.82
Then 8.5.2

Cummins INSITE 8.5.0.57 Software with Patch:

Source:
With patch.

Cummins INSITE 8.5.0.57 Software installation on win7:
OS: win7 32
Language: multi-lingual

Cummins INSITE 8.5.0.57 is compatible with INLINE 6, INLINE 7, DPA5, NEXIQ, NEXIQ2.
Please watch video on how to install Cummins Insite 8.5.0.57 for nexiq:

Enjoy!

2019/08/21

How to setup Cummins Insite 8.5.0 on Windows 7?

Cummins Insite 8.5.0 is released and tested OK with Inline 6 and Inline 7 HQ china clone.
Here’s the installation instruction of Insite 8.5.0.57 program + driver + patch and test report on Inline 6 adapter. Hope it’s helpful.

you should have:
folder: drives
zip file: INSITE 8.5.0
zip file: INSITE 8.5.0 patch
install-cummins-insite-850-sw-1

operating system:
windows 7 32 bit: tested!
(need luck for other windows edition)

youtube video:

steps to install cummins insite 8.5.0:

step 1: install insite 8.5.0 program
step 2: install driver for cummins inline 6
step 3: install insite 8.5.0 patch

in detail…

step 1: install insite 8.5.0

establish a new folder: 8.5 on Desktop
extract INSITE 8.5.0.exe to the new folder 8.5
open folder 8.5
run AdminInstall as admin
select a setup language (here: English)
install-cummins-insite-850-sw-2
start to install insite 8
install-cummins-insite-850-sw-2
items required to install:
Microsoft.NET Framework 4.7.1 Full
Microsoft_Visual_C++_2017_Redistributable_Package_(x86)
TooLicenseService
INSITE Data Pack

start to install items one by one
note 1: accept insite software license agreement
note 2: insite data pack is installed successfully
install-cummins-insite-850-sw-3
finish, but you will get an error: some files may be missing from the installation or computed. please reinstall or repair and relaunch application
leave the error aside and continue your installation
note 3: install insite – installshield wizard
next – tick on “I have verified…”, next – accept the license agreement, next – next – install
install-cummins-insite-850-sw-4
insite is installed successfully
install-cummins-insite-850-sw-5
finish

automatically install insite 8.5.0, insite manager, fault viewer
install-cummins-insite-850-sw-6
then click on OK on the error

go to folder 8.5 – UpdateManager
open fix application
go to Help –fix bug, then exit
install-cummins-insite-850-sw-7

step 2: install insite 8.5.0 driver

go to Computer Properties to confirm your system type
here: 32 bit operating system
install-cummins-insite-850-sw-8
go to the removable disk INISTE 8.5.0, then folder drives – inline 6 drivers
open the zip file: inline-6-9-0-0-32bit, then do extraction from it
automatically running…
will install Cummins INLINE 6 -32bit on your system
next…
finished installing Cummins INLINE 6
finish

step 3: install insite 8.5.0 patch

copy the zip file INSITE 8.5.0 patch from the removable disk to Desktop
extract the pactch file on Desktop, then open the folder
open “康明斯8.5.0注册” (cummins 8.5.0 registration) application
install-cummins-insite-850-sw-10
install-cummins-insite-850-sw-11

accept cummins license agreement
cummins inline 6 driver software will  be installed automatically

step 4: configure cummins inline 6 connection

open Cummins INSITE app
accept insite software license agreement
add new to create a connection to a datalink adapter or ecm simulator
install-cummins-insite-850-sw-12
rp1210 adapter: connect using a rp1210 adapter
install-cummins-insite-850-sw-13
connection settings:
vendor: cummins inc. inline 6
adapter: inline 6 usb
protocol: auto detect
install-cummins-insite-850-sw-14
connection name: INLINE 6.USB (Auto Detect) Connection
to make this connection active, select this box and then click FInish
install-cummins-insite-850-sw-15
successfully configured the new connection

connect
install-cummins-insite-850-sw-16
install-cummins-insite-850-sw-17
fault codes in cummins insite 8.5.0
install-cummins-insite-850-sw-18
inline 6 clone adapter is confirmed to work with insite 8.5.0.
aslo, it can be used with Cummins inline 7 china clone. tested and worked good.

2018/12/05

Cummins INSITE 8.2 Download for Inline 4/5/6/7 Adapters

Free download Cummins INSITE 8.2 with installation and activation help to make it work with new and old inline 4/5/6/7 adapters. Here are two versions for you, one with free activation for 15-day trials only, the other with 500 times to use once activated.

Part 1: Insite 8.2 FREE version:

Here is the Cummins INSITE 8.2.X installer that tests all levels of functionality
Members copy patch files to C/Intelect/INSITE/XMLData folder and shortcut to desktop
Copy code gives me free activation 15 trials.
UNKNOWN SECURITY! You’re trying the free insite at your own risk!


Cummins INSITE 8.2+Full KG PRO top, fleet calibration and flash ecm feature list
1. Authorization file generator
2. Username generated authorization file
3. Is it bound to a computer (Cancel is not limited to computers)
4. Lock the CPU to lock the serial number of the hard disk
5. Bind the MAC Address to the BIOS Information
6. Check the limit and enter the appropriate value. Unchecked is no limit.
7. Valid expiration time
8. Limit once per minute
9. Limits can run for a total of minutes
10. Limit attempts to limit trial dates


Part 2: Insite 8.2 TESTED version:

Here is the 100% tested version. You can use the Insite 8.2 pro or lite version with security and relief. You have 500 times for use once your insite is activated.

Insite 8.2 remote installation & activation service:
cummins-insite-v820-download
A good tip: Iniste pro vs Insite lite

Insite 8.2 installation help:
You will have luck with Windows 7/8/10. But on Windows 10, pls run as administrator

Insite 8.2 and Inline 4/5/6/7 adapters:

Inline 5: no longer produced

Do not substitute cables, except as indicated in the INLINE 5, 6, or 7 Product Announcement Bulletin.
Incompatible cables may damage the INLINE 5, 6, or 7 adapter or personal computer and will void warranty.
Incompatible cables may cause communication issues with INSITE.
INLINE 5, 6, and 7 adapters may intermittently lose communication. If your Datalink adapter has communication problems, disconnect power from the adapter for 5 seconds and then reconnect. The INSITE program does not need to be shutdown.
There is a feature under Tools > Reset Datalink Adapter that may correct some software communication errors with the INLINE 5, 6, and 7.
The main harness (backbone) has a maximum overall length of 40 meters.
A J1939 stub, which can be a connection point for ECM’s and/or the INLINE 5, 6, and 7 Datalink adapter, cannot exceed a maximum length of 1 meter.
At each end of the backbone harness is a terminating resistor with a nominal resistance of 120 Ohms, it will measure 60 Ohms when you measure across the Datalink.
The INLINE 5, 6, and 7 adapters should be connected to a continuous battery power supply. When making adjustments with INSITE, including calibration download, the operator will be asked to switch the key off. If the adapter is getting its power from a power source dependent on the key switch status, such as the lighter adapter inside the cab, the adapter will lose power, which will result in INSITE losing connection to the ECM. This will require the operator to reconnect to the ECM and the adjustments might not have been saved.

Insite 8.2 protocols:
Engine Model Years 2007 and newer only support the J1939 protocol. Please refer to the following table for specific information:
cummins-insite-protocol
Note: The INLINE 4 adapter is obsolete. It can be used with INSITE, but technical support for this adapter is no longer available.

INSITE 8.2.0 released notes:
1  Opening INSITE
  1. Installation
  2. Connections
  3. Advanced ECM Data
5.Calibrations
  1. Display Graphics
  2. ECM Diagnostic Tests
  3. Fault Codes
  4. Printing
  5. Simulators
  6. INSITE Integrated Simulator – Single and Multi-Module
  7. Work Orders/ECM Images/Templates

In detail…

1 Opening INSITE
INSITE 8.2.0 takes longer to open if the computer has been restarted. Issue is currently under investigation.

2 Installation
INSITE 8.2.0 does not support Windows® XP or Windows® Vista. INSITE version 8.2.0 will only operate on PC’s running either Windows® 7, Windows® 8 or Windows® 10.

Refer to the table below for the hard drive space required for the installation of
INSITE 8.2.0. This is based on the assumption that the Operating System is installed
on C:\

Hard Drive Space Requirements
– Upgrade from 8.1.3: 350MB
– Fresh Install: 500MB

NOTE: It is highly recommended that you always reboot your PC after installing software

3 Connections
Error Messages for communication failures:
Error 5200: Indicates communication loss between computer and the datalink adapter.
Error 5201: Indicates communication loss between the datalink adapter and the ECM.
Error 5202: Indicates no communication could be established between the datalink adapter and the computer.
Error 5204: Indicates no communication could be established between the datalink adapter and the ECM.

If the “Auto Configure” and/or “Datalink Adapter Connection Test” do not find the adapter when connected, manually configure the Datalink adapter connection.
An Internet connection is required before selecting the following URL’s from the Help > About INSITE menu: http://www.cummins.com or http://insite.cummins.com

4 Advanced ECM Data
If the display becomes distorted or cannot be completely viewed, close the Advanced ECM Data window and then reopen it. Resizing the window can cause the view to become distorted.

5 Calibrations
Automotive applications will have a default setting of “ON” for the Save and Restore option in the Calibration Download dialog.
Industrial applications will have a Default Setting of “OFF” for the Save and Restore option in the Calibration Download dialog.
When performing a Calibration Download, the “Save and Restore” option may be grayed out for some applications.
To decrease calibration download times, please insure that all applications other than INSITE are closed. Always use the J1939 protocol and engine connector when available.
Computers with less than the minimum recommended hardware requirements will have an extended Calibration Download time. Screen savers and suspend modes should be disabled

6 Display Graphics
The use of Large Toolbar Buttons will not display all icons on the toolbar. Work Around: Under Tools > Options > General, select Small Buttons in Display Options.
Dual Monitors are not supported by INSITE.
To disable the “Display Feature Names” option for the view bar, uncheck the box in Tools > Options > General > Viewbar > Display Feature Names.
If your PC monitor display is set to “Large Fonts”, some information in INSITE may not be displayed. It is recommended to use small fonts.

7 ECM Diagnostic Tests
If the display becomes distorted or cannot be completely viewed, close the ECM Diagnostic Tests window and then reopen it. Resizing the window can cause the view to become distorted.

8 Fault Codes
The MIL Lamp Status is not displayed when printing the Image Fault Codes in Tool Display Format.
Work Around: Print the Image Fault Codes in Text Only Format or connect to the image, open Fault Codes and select the Print icon.

9 Printing
When using print preview, use the tool bar magnifying glass to display the text in a larger view. The Print options will be disabled when no printers are available. This includes the Page Setup, Print and Print Preview options. Work around: Setup/install a printer on the PC and retry the INSITE print selection.

10 Simulators
Values shown in simulator do not reflect real values that would be seen when connected to an engine.

11 INSITE Integrated Simulator – Single and Multi-Module
All simulators for the 2007 models and above were combined into one single simulator called INSITE Integrated Simulator – Single Module and INSITE Integrated Simulator – Multi-Module. These will display all the Features and Parameters, ECM Diagnostic Tests, and Advanced ECM Data that is supported for single and multimodule engines.

12 Work Orders/ECM Images/Templates
Double clicking on the exported image files (.csv format) will not open them with the correct format in Microsoft Excel. Work around: Follow the steps below to open an exported (.csv format) image file in Excel:
  1. Open the .csv image file with Microsoft Excel
  2. Highlight column A
  3. Click on Data > Text to Columns
  4. In Step 1 of the wizard, make sure the “Delimited” option is selected and click “Next”
  5. In step 2 of the wizard, uncheck the “Tab” box and check the “Comma” box and click “Next”
  6. In step 3 of the wizard, click on “Finish”
  7. Format columns as desired.
When upgrading to INSITE 8.2.0, the following file and folder need to be backed up:
C:\Intelect\INSITE\UserSettings\data.wo
C:\Intelect\INSITE\WorkOrders
Alternatively, select the “Export All” from the right-click menu while highlighting any Image.
When using templates, it is recommended to verify the first template sent to the target vehicle. This helps ensure the template configuration is correct for subsequent vehicles.
When using templates, verify that the ECM code is compatible or the same.
When naming images and templates, special characters cannot be used (i.e. & ^, etc.).

Insite 8.2 images:
cummins-insite-v820-software-1

cummins-insite-v820-software-2

cummins-insite-v820-software-3

cummins-insite-v820-software-4

cummins-insite-v820-software-5
http://blog.obdii365.com/2018/12/06/cummins-insite-8-2-download-free-version/

2018/11/05

How to Install Cummins Insite 8.3 Pro Software with KG

Here is the Cummins insite 8.3 that been going around with the KG. All here is for the purpose of education and help.

Insite 8.3 download links: Link 1: Insite 8.3 Pro with Kg
Youtube video: Insite 8.3 Install
(BIG THANKS FOR GHOST MAN)
Cummins Insite 8.3 installation instruction:
Read the all the instructions and your clue is at the end. Please don’t ask me for the password for the zip files

1 install Cummins Insite 8.3
2 Rename primary Insite icon ” DOWNLOAD ICAL files only ”
cummins-insite-83-software
3 Copy the Instie crack program to Desk and double click open it
4 Copy hwid from activator to keygen with
cummins-insite-83-keygen-id
5 Put any user name you want
cummins-insite-83-generate-name
6 generate key place key and name in activator
cummins-insite-83-generate-key
7 run activator as admin
8 start icon should open up
9 hit start insite logo should show
10 when the activate licence window opens up click simulator mode
11 make sure internet is on for first activation
12 other time activate licence window open click simulator it will still work correct no active licence ever show but it will work like dealer lisenced pro.   Password to open main zip file MmhaUuto!$theSh!t Password to open second zip ThankYouGhostman!!


Insite 8.3 Question and Answers: 
Q: Insite 8 installation was done perfectly without issue. But when trying to connect any ECU – Insite asks about license for connecting.
cummins-insite-83-connect-error
A: Don’t use original icon. Use loader and run as admin.

Q: This is version 8.3. error 50005
cummins-insite-83-error-50005
A: Uninstall everything including folder in c drive reinstall connect to internet the first timehit simulator and run as admin might even have to make exemption in antivirus. It works well but if you are running windows defender it can cause some communication issues I have found. For the best solution but not free solution contact zdssf

Q: I could install perfectly here, but I have a problem. When I do the download of calibration files they are found on the net, I click save but they do not save anywhere on the computer. Has anyone ever experienced this?
A: All the calibrations can be downloaded from:
https://www.cummins.com/parts-and-servic…ools/incal
Save them to the cal workspace folder and you have them all to rummage through as you need.
I have always found this to be much easier.

Q: works with nexiq usblink interface?
A: Yes. I run it with genuine nexiq 2 or inline 6 data link adapters.

Q: How to obtain the registration name for the keygen
A: Just put anything in there like you name. i just use my computer id. same as middle box. i know the video is clear as mud. https://www.youtube.com/watch?v=_X2fJbbNJBo
watch it a few times and that is all it does. this works good when you are done. when it launches insite
use the the bottom button. once in simulator mode pick your data link.and connect. just like a licensed copy.



– Very good work

– mine is still working and it’s been almost 2 months

– been playing around with this.
seems to work ok. flashed a truck with it today with no problems

– If people can follow directions for activation it will work fine for them you can upgrade the fis with 8.4 and have a pretty a solid program it was a good share. For many people here because 7.6 was going by way of the dinosaur. Now the members here have a way to work on the new stuff.

Insite 8.3 tech support:

http://blog.obdii365.com/2018/11/05/how-to-install-cummins-insite-8-3-pro-with-kg/