2024/07/23

Install Yanhua ACDP Module 34 MQB RH850 Interface Boards

 Yanhua Mini ACDP released new Module 34 for VAG MQB RH850 immo key programming and mileage correction.  Module 34 contains 9 interface boards, including:

D70F3423 x1
D70F3426 x3
R7F71401 x1
R7F71402 x1
R7F71404 x1
R7F71406 x1
R7F71407 x1

 

They are compatible with ACDP 1 and ACDP2 host.

 

Module 34 Functions
1: Supports Immobilizer and mileage repair for 4th generation meters with D70F3423/D70F3426 chip models.
2: Supports Immobilizer and mileage repair for R7F71401,  R7F71402, R7F71407 5A meters (also called RH850)
3: Supports mileage repair for R7F71401, R7F71402, R7F71404, R7F71406, R7F71407 5C meters (also called RH850)

yanhua mini acdp module 34

Here we show how to interface these interface boards.

 

Install MQB RH850 R7F701402 Interface Board

1. Find the interface board installation area on the instrument according to the visual positioning mark on the interface board.

Install MQB RH850 R7F701402 Interface Board 1

2. Find the correct positioning holes of D1 on the instrument.

Install MQB RH850 R7F701402 Interface Board 2

3. Align the interface board with the screw fastener holes and D1 positioning points

Install MQB RH850 R7F701402 Interface Board 3
4. Press the interface down with your left hand.
Tighten the locking screw with your right hand.

Install MQB RH850 R7F701402 Interface Board 4
5. Confirm again that the interface board D1 positioning pins are completely aligned with the D1 positioning holes of the instrument.

Install MQB RH850 R7F701402 Interface Board 5

 

 

Install MQB RH850 R7F701407 Interface Board

1. Push all PCB lock fastening on the interface board to the unlock position

Install MQB RH850 R7F701407 Interface Board 1

2. Find the interface board installation area on the instrument

Install MQB RH850 R7F701407 Interface Board 2
3. Find the correct positioning holes of D1, D2, D3 on the instrument

Install MQB RH850 R7F701407 Interface Board 3
4. Check that the D1 and D2 positioning pins are completely aligned with the D1 and D2 positioning holes of the instrument and ensure that the PCB lock buckle is completely aligned

Install MQB RH850 R7F701407 Interface Board 4
5. Push the PCB lock buckle to the Locked position to lock the interface board
Interface board installation is done.

Install MQB RH850 R7F701407 Interface Board 5
6. Confirm again that the interface board D1, D2, D3 positioning pins are completely aligned with the D1 and D2 positioning holes of the instrument.

Install MQB RH850 R7F701407 Interface Board 6

 